And finally, I was informed Ra will make any rubber seals such as in Schrader valves smaller, again resulting in more leaks. Was that it? Does it just come down to more leaks and recovery problems?

Understand this: The mineral oil in a compressor has a vapor pressure. Yet, the company spokesperson assured me that mixing Ra and R22 combines their pressures and reaches a lower median. Is that true? Not according to the gas laws I used to teach.

Rather, the books I taught from say that each refrigerant reaches its own vapor pressure. It will just flood back to reduce the compressor life and will greatly reduce the system capacity. Do I have an answer? No, but I suspect that mixing the two refrigerants is a terrible idea. Meanwhile, hundreds, thousands and soon millions of air conditioners may be contaminated in this way. He has worked in contracting, for supply houses, and for national equipment manufacturers.

He has served as an industry teacher on technical topics, and as a writer and editor. She can be contacted at or joannaturpin achrnews. This website requires certain cookies to work and uses other cookies to help you have the best experience. By visiting this website, certain cookies have already been set, which you may delete and block. By closing this message or continuing to use our site, you agree to the use of cookies.

Visit our updated privacy and cookie policy to learn more. This Website Uses Cookies By closing this message or continuing to use our site, you agree to our cookie policy. Learn More This website requires certain cookies to work and uses other cookies to help you have the best experience. October 22, Report Abusive Comment Thank you for helping us to improve our forums. Is this comment offensive? Please tell us why. Restricted Content You must have JavaScript enabled to enjoy a limited number of articles over the next 30 days.

Please click here to continue without javascript.. No prices either. There is NO, it should be at this pressure. And now that you mixed the gasses. You have a cocktail mix. That no one knows what anything should read. Join Date Jun Location west point, ga. Yea get someone to fix the leak now and you won't have to worry about cooling your house anymore.

Originally Posted by beenthere. Put 5 more cans in while smoking a cig and call me in the morn. Originally Posted by snupytcb. With that cocktail. Its more problem then just outside temp. More leaks are in the coils, then in line sets. You just gave another good reason not to use that HAVC company. Mixing refrigerants is a violation of EPA regs. Just because they are blowing out the same temps, doesn't mean they should be.

Air flow, effects coil temp difference. And since it isn't, its putting more load on teh other unit. Yes, it must be recovered, vavuumed, and recharged with new R22 only. I wouldn't use that company again, if mixing gasses is their normal answer to a leaking system.

DIY - not here. Don't post it again. This thread is closed.